Fire Safety Testing Equipment
Comprehensive range of fire safety testing machines designed and manufactured to meet all BIS standards with superior accuracy and reliability.
Below are the Indian Standards and indicative key tests our equipment supports across core fire-protection categories.
| Item | IS Code | Key Tests (indicative) |
|---|---|---|
| Portable Fire Extinguishers (water/foam/CO₂/powder/clean agent) | IS 15683:2018, IS 2190 | Hydrostatic burst & proof tests, crushing, pressure cycling, gauge calibration, safety device checks, mounting/handle/bracket strength, hose assembly tests, discharge performance (time, range/throw), leakage and marking verification. |
| Automatic Sprinkler Heads | IS 9972:2002, IS 15105:2021 | Orifice & K-factor verification, service load and frame strength, deflector strength, water flow & endurance, distribution pattern, thermal response/classification, leakage & seat tightness, finish/marking. |
| Non-percolating Flexible Fire-Fighting Delivery Hose | IS 636:2018 | Proof & burst pressure, adhesion (lining/cover), elongation & kinking, flexibility, leak tightness, dimensions, ozone/aging where applicable, marking. |
| Hydrant Landing Valves (internal hydrants) | IS 5290:1993 | Body material checks, hydraulic strength & water-tightness, seat/leak tests, dimensions of female instantaneous outlet, operating torque, corrosion protection & markings. |
| Fire Hose Delivery Couplings, Branch Pipe, Nozzles & Spanner | IS 903:1993 | Dimensional conformity of 63/70 mm couplings, hydrostatic & leak tests, tensile/deflection for branch pipe, nozzle bore accuracy (6–30 mm), interchangeability, surface finish & marking. |
| Hydrant Systems — Installation, Inspection & Maintenance | IS 3844:1989, IS 13039:2014 | Commissioning/acceptance: pump capacity & flow test at remote point, residual pressure checks, control valve function, hose reel operation, signage & coverage verification, inspection/maintenance schedules. |
| Automatic Fire Detection & Alarm Systems (AFDAS) | IS 2189:2008 (reaffirmed 2018) | Control & indicating equipment performance, power supply/battery autonomy, detector response & alarm verification, sounder audibility, fault monitoring, cause-and-effect program tests, documentation & maintenance. |
| Smoke Detectors (optical/ionization) | IS 11360:1985 | Sensitivity & response (obscuration/scatter), environmental conditioning (temperature/humidity), false-alarm immunity, endurance, constructional checks & marking. |
BIS standards & key tests for fire safety (Extinguishers, Sprinklers, Hose, Hydrants, Alarms & Detectors)
Our Fire Safety Testing Equipment
Browse our range of specialized fire safety testing machines designed for laboratory and field applications.
Fire Safety Testing FAQs
What Fire Safety Testing Machines do you supply?
- Extinguisher cylinder rigs: hydrostatic burst/proof, crush, pressure cycling, leakage & gauge calibration
- Discharge/throw measurement setups, bracket/handle strength jigs
- Sprinkler head benches: service load, frame/deflector strength, water flow & endurance, distribution, thermal response
- Hose proof/burst pressure rigs, adhesion & elongation/kink fixtures
- Landing valve hydrostatic & seat-tightness testers, torque test fixtures
- Coupling/nozzle testers for hydrostatic/leak and dimensional checks
- AFDAS functional test kits (detector response, loop integrity), sound level checks, power autonomy verification
Which IS standards map to my categories?
- Portable Fire Extinguishers — IS 15683 (product), IS 2190 (selection/installation/maintenance)
- Automatic Sprinkler Heads — IS 9972, System Design — IS 15105
- Fire Hose (Delivery) — IS 636
- Hydrant Landing Valves — IS 5290
- Couplings, Branch Pipe, Nozzles — IS 903
- Internal Hydrants & Hose Reels — IS 3844, External Hydrants — IS 13039
- Fire Detection & Alarm — IS 2189 (system), Smoke Detectors — IS 11360